P4200W Series Dehydrators
Up to 4200 SCFD
NEBS Compliant
Standard Features: |
---|
|
Optional Features: | |
---|---|
|
Accessories: | |
---|---|
|
General Specifications: | ||||||
---|---|---|---|---|---|---|
P4200W | P4200WLP | P4202W | P4202WLP | |||
Output Capacity | Normal: 2,600 SCFD (74 SCMD) Continuous Maximum: 4,200 SCFD (119 SCMD) Emergency |
|||||
Power Requirements (15 Amp Service Recommended) |
110 - 125 VAC, 50/60 Hz | 220 - 230 VAC, 1-Phase, 50/60 Hz | ||||
Running Amps | 8.6 Amps | 3.9 Amps | ||||
Outlet Pressure Range | 5 - 20 PSIG (35 - 138 KPa) |
0.30 - 10 PSIG (2 - 69 KPa) |
5 - 20 PSIG (35 - 138 KPa) |
0.30 - 10 PSIG (2 - 69 KPa) |
||
Outlet Air Relative Humidity | Less than 2% RH | |||||
Compressor Type | Two-Cylinder, 3/4 HP, Oil-less Type | |||||
Dehydrating Method | Heatless Desiccant | |||||
Environment Operatating Temperature Range | 40° - 85°F (5° - 30°C) Ambient *Unit will go into SHUTDOWN Mode if Cabinet Temperature exceeds 120°F (49°C) |
|||||
Noise Level | 63 dBA at 3’ (1 m) | |||||
Heat Dissipation | 3,500 BTU/hr | 2,900 BTU/hr | ||||
Alarms | Standard Alarms - Complete readings of all critical measurement points, individual alarm indication display, including SNMP Communication | |||||
Outlet Connections | 1/2” NPT Female | |||||
Dimensions | 21” D x 25.5” W x 49” H (53.3 cm D x 64.1 cm W x 124.5 cm H) | |||||
Weight | 222 lbs (100 kgs) |
Literature: |
---|
P4200W Series Specification Sheet |
Guides: |
P4200W Series User's Guide P4200W Series Installation Guide P4200W2 Series User's Guide (Metric) for W2 models with Metric-specific Control Boards |
Firmware Files: *This is the latest production Firmware for our current version Control Boards ONLY. Please Contact Altec AIR for all other Product Firmware requirements. |
P4200W Series Firmware Files |
SNMP Files: |
P4200W Series MIB Files for use with P4200W models using Firmware versions 0.5.4 or newer |